8

year

Follow us :

Battery Drop Weight Impact Testing Machine

Battery Drop Weight Impact Testing Machine
Battery Drop Weight Impact Testing MachineBattery Drop Weight Impact Testing MachineBattery Drop Weight Impact Testing MachineBattery Drop Weight Impact Testing MachineBattery Drop Weight Impact Testing Machine
group name
Battery Test Machine
Min Order
1 piece
brand name
HUDA Test Machine Manufacturer
model
HUD-H206
Nearest port for product export
ShenZhen, HK
Delivery clauses under the trade mode
FOB, CFR, CIF, EXW, FAS, CIP, FCA, CPT, DEQ, DDP, DDU, Express Delivery, DAF, DES
Acceptable payment methods
T/T, L/C, D/P D/A, Cash
update time
Mon, 27 Sep 2021 10:24:16 GMT

Paramtents

  • Weight 9.1kg and 10kg

  • Height 0-1000mm (can be set)

  • Impact method free fall

  • Internal material SUS#304 stainless steel plate, thickness 1.2mm

  • Control mode PLC touch screen control

  • Displacement accuracy ≤±5mm

Packging & Delivery

  • Min Order1 piece

Briefing

Battery impact test machine tests the safety performance of battery by different weights

Detailed

Application

The battery of the test sample shall be placed on a flat surface, and a rod with a diameter of 15.8 ± 0.2 mm (5/8 inch) shall be placed on the center of the sample in a crisscross pattern. A 9.1kg or 10kg weight dropped from a certain height (610mm or 1000mm) onto the sample. When a cylindrical or square battery is subjected to an impact test, its longitudinal axis should be parallel to the plane and perpendicular to the longitudinal axis of the steel column. The longest axis of the square battery is perpendicular to the steel column, and the largest surface is perpendicular to the impact direction. Each battery only accepts one impact test. If the battery does not catch fire, it is qualified if it does not explode.

Standards

UL1642: 2012, UL 2054 "Lithium Battery Standard"

UN38.3 "Lithium Batteries and Battery Pack Testing Standard Regulations"

IEC62133GB/T 18287-2013 "General Specification for Lithium Ion Batteries for Cellular Phones Heavy Object Impact Test"

GB 31241-2014 "Safety requirements for lithium-ion batteries and battery packs for portable electronic products"

GB-31241-2014 "Safety Requirements for Lithium Ion Batteries and Battery Packs for Portable Electronic Products"

QB/T2502 "General Specification for Lithium Ion Batteries"

Main Parameters

1. Weight

 9.1kg and 10kg;

2. Height

 0-1000mm (can be set);

3. Display

 LED meter display;

4. Displacement accuracy

 ≤±5mm;

5. Impact method

 free fall;

6. Control mode

 PLC touch screen control;

7. Impact floor material

 No. 45 steel, thickness 30 password;

8. Metal rod

 15.8±0.2mm (5/8 inch) steel rod;

9. Internal material

 SUS#304 stainless steel plate, thickness 1.2mm; Teflon melt adhesive tape is applied to 1/3 of the place, high temperature resistance, corrosion resistance, insulation and easy to clean.

10. External material

 cold-rolled sheet baking varnish treatment, thickness 1.5mm;

11. Pressure relief door size

 200x200mm;

12. Smoke exhaust pipe

 diameter φ100mm, located at the back of the box;

13. Box door

 a single door opens to the left, and an explosion-proof chain is installed on the side of the box door;

14. The maximum size of the battery tested

 200x200x200mm (width x depth x height);

15. Inside dimensions

 490x520x1430mm (width x depth x height);

16. Outside Dimensions

 700x1000x1720mm (width x depth x height, including door lock);

17. Impact method

 lift the falling ball to a certain height and release it, and the falling ball falls freely in the vertical direction, without tilting or shaking;

18. Power supply

 1, AC220V, 3A

19. Power supply power

 700W

20. Weight (approximately)

 about 270kg