4 Circulatory System
Check the pump and connecting lines for leaks. The drain tank should be free of sediment. Clean the pump and thoroughly clean the tank.
5 Control System
This is the more precise part of the constant temperature and humidity chamber, which may require software updates and bug fixes. You can contact the manufacturer for corresponding maintenance.
Lastly, check the overall construction of the chamber: the exterior, work area and floor for perforations, tears and dents. Check all gaskets for degradation: doors, windows, ports and plugs.
Check the seal at each seam. Check the integrity of the panel lock or latch. Verify that door operation produces a smooth seal by checking latches and latches and hinges. Clean drain pipes and condensate pump. Clean and adjust air conditioners, vacuum or blow motor and mechanical areas to remove all dust and debris. Replace any missing or damaged safety labels. Return the test chamber to the correct position, leaving 12 to 36 inches of space for optimal airflow for optimal test performance.
Checking the constant temperature and humidity chamber by regularly , test can be carried out more accurately.